ABSTRACT


In this study, micro-electro-mechanical-systems (MEMS) fabrication technology was employed to fabricate an array of micro sensors to monitor the temperature and humidity in situ within the membrane electrode assembly (MEA) of fuel cells. The advantages of array-type micro temperature and humidity sensors are not only their small size enabling them to be placed on MEA, but also their high sensitivity and accuracy preserved at the same time. The experiment involves temperatures from 30 to 100 ºC, the resistance varied from 51.80 to 57.06 Ω. The accuracy and sensitivity of temperature sensor is less than 0.3 ºC and 1.5 10-3/ºC. The humidity sensor showed that the capacitance changed from 37.05 to 39.51 pF, the relative humidity from 20 to 95%RH, and the accuracy and sensitivity is less than 0.25%RH and 0.03 pF/%RH.


Keywords: MEA, MEMS, Micro Sensors


REFERENCES


  1. [1] Larminie, J. and Dicks, A., Fuel Cell Systems Explained, second ed., John Wiley & Sons, Chichester, West Sussex, UK, pp. 2566 (2003).
  2. [2] Cho, E. A., Ko, J. J., Ha, H. Y., Hong, S. A., Lee, K. Y., Lim, T. W. and Oh, I. H., “Characteristics of the PEMFC Repetitively Brought to Temperatures Below 0 C,” J. Electrochem. Soc., Vol. 150, pp. A1667 A1670 (2003).
  3. [3] Gasteiger, A., Gu, W., Makharia, R., Mathias, M. F. and Sompalli, B., Beginning-of-life MEA Performanceefficiency Loss Contribution, in: Handbook of Fuel Cells, Wiley, pp. 593610 (2003).
  4. [4] Wang, M. H., Guo, H., Ma, C. F., Ye, F., Yu, J., Liu, X., Wang, Y. and Wang, C. Y., “Temperature Measurement Technologies and Their Applications in the Research of Fuel Cells,” Proceedings of the First International Conference on Fuel Cell Science, Engineering and Technology, Rochester, NY, USA, pp. 95100 (2003).
  5. [5] Vie, S. P. J. and Kjelstrup, S., “Thermal Conductivities from Temperature Profiles in the Polymer Electrolyte Fuel Cell,” Electrochem. Acta., Vol. 49, pp. 1069 1077 (2004).
  6. [6] He, S., Mench, M. M. and Tadigadapa, S., “Thin Film Thermal Sensor for Polymer Electrolyte Fuel Cells,” Proceedings of the 206th Meeting of The Electrochemical Society, Microfabricated Systems and MEMS VII, Honolulu, HI, USA, pp. 244253 (2004).
  7. [7] Mench, M. M., Burford, D. J. and Davis, T. W., “In Situ Temperature Distribution Measurement in an Operating Polymer Electrolyte Fuel Cell,” Proceedings of 2003 ASME International Mechanical Engineering Congress, Heat Transfer Division, Washington, DC, USA, pp. 415428 (2003).
  8. [8] Burford, D. J., “Real-Time Electrolyte Temperature Measurement in an Operating Polymer Electrolyte Membrane Fuel Cell,” Master thesis, The Pennsylvania State University, University Park, (2004).
  9. [9] Nishikawa, H., Kurihara, R., Sukemori, S., Sugawara, T., Kobayasi, H. and Abe, S., “Measurements of Humidity and Current Distribution in a PEFC,” J. Power Sources, Vol. 155, pp. 213218 (2006)